Short Description: 1. DC Max Input Current:0-60A 2. Input Frequency Range: 45Hz ~65Hz 3. DC Output Current:0~100A 4. DC Output Voltage: 200Vdc ~1000Vdc 5.DC Output Power: 30KW@ Voltage 6. Operating Temperature:-40℃~+75℃ 30KW @1000V Charger Power Module is specially designed for EV DC chargers. It has high efficiency, low fan noise, high power density and high reliability advantage.
Product Description
1.Characteristic curve
2.Functional details
2 .1Short-circuit protection
After short circuit, the module will automatically shut down the protection (three short circuit lock mode: no output after protection, it can be restarted after 10 seconds. If it occurs again after three restart within 5 minutes, the module will lock and stop the output until the power is restored manually).
2.2 Output overvoltage protection
High voltage mode 1010V ± 10V; low voltage mode 510V ± 10V (four overvoltage lock mode: the module has no output after protection, the module can restart after 5 seconds, if the overvoltage occurs again after four restart within 5 minutes, the module will lock and stop the output until the power is restored manually).
2.3 Output undervoltage protection
High V mode 50V ± 5v; low V mode 25V ± 5V (no output after protection; command boot after recovery).
2.4 Input overvoltage protection
490 Vac ± 5V, 15V return difference (no output after protection; a command is required to boot after recovery).
2.5 Over-temperature protection function
The detection temperature reaches the preset value (no output after protection; command boot after recovery).
2.6 Input is missing phase protection
No output after protection; command to be started after recovery (no output after protection; command to be started after recovery).
2.7 Fan control
Control the fan speed according to ambient temperature and output current (automatic speed).
2.8 Remote communication
The protection signal of the module (AC, undervoltage, phase deficiency, output, undervoltage, overtemperature) and fault signal are transmitted to the background monitoring software in real time.
2.9 Remote monitoring
Feedback the real-time signal (voltage, current, power, temperature); the flow signal of each module to the background monitoring software.
2.10 Remote control
By the background monitoring software control module to turn on and off, both / floating charge conversion.
2.11 Remote adjustment
Adjust the current, pressure and power limit by the background monitoring software.
3.Technical Parameters
Product model |
DD100030 |
||
Ambient condition |
working temperature |
-40℃ ~ + 70℃; -40℃ (± 4℃) module starter; 55 (± 2℃)℃ The above derated use; Above 70℃ (± 4℃) for shutdown |
|
storage temperature |
- 40℃~85℃ |
||
relative humidity |
95%, with no condensation |
||
The atmospheric pressure is at an altitude of |
79 kPa ~ 106 kPa; altitude <2000m; drop above 2000m The amount of use |
||
cooling-down method |
Intelligent air cooling |
||
Input Characteristics |
input voltage |
Three-phase line voltage 260 Vac ~ 485 Vac; undervoltage below 260 Vac, overvoltage above 485V, 260V ~320V drop, 320V ~485V full load output |
|
incoming frequency |
55 Hz±10Hz |
||
Input power factor |
≥0.98 |
||
Total harmonic distortion rate of the input current |
5% (above half-load) |
||
productiveness |
95% (25 degree rated input / output full load efficiency) |
||
Standby power consumption |
10W |
||
Input current overshoot |
Peak input current Rated input current is 110% |
||
number of phases |
Three-phase + protected area |
||
input currenton |
0~60A |
||
Output Characteristic |
|
High pressure mode |
Low pressure mode |
Stable voltage output voltage regulation range |
(200~1000)Vdc |
(150~500)Vdc |
|
Rated output voltage |
1000V |
500V |
|
Rated output current |
30A |
60A |
|
Adjustment range of current-limiting value |
0.5A ≤I≤60A |
0.5A ≤I≤100A |
|
Output voltage ripple factor (25℃) |
≤1% (500Vdc~1000Vdc) |
≤1% (200Vdc~500Vdc) |
|
Normal boot mode: startup time |
3s≤t≤8s |
3s≤t≤8s |
|
Stable flow accuracy |
≤±1% |
≤±1% |
|
Stable pressure accuracy |
≤±0.5% |
≤±0.5% |
|
Me-flow imbalance |
5% Rated output current (at 10%~100% load) -universal relevance |
5% Rated output current (at 10%~100% load) -universal relevance |
|
Newsletter Alarm |
Communication interface |
C AN |
|
Maximum number of machines |
60 |
||
Warning and status |
Report the monitoring background via CAN bus or display in the panel LED |
||
Physical Characteristics |
Noise |
<65dB (25℃, full load rated output) |
|
Cooling-down method |
Intelligent air cooling |
||
Outline dimension |
84mm * 300mm * 437.5mm (width * height * depth) |
||
Quality |
≤17kg |
||
MTBF |
400,000 hours (40℃) |
||
Insulation resistance
|
The test voltage is 1000 Vdc, and the insulation resistance of the AC input to the case, the DC output and DC output to the case is> 100M Ω |
||
Insulation strength
|
AC input to the case 3500 Vdc, DC output to the case and AC input output 4200 Vdc, 1 minute, no breakdown, no flying arc phenomenon, steady state leakage current less than 10 mA. |
||
Safety & EMC Standard |
GB/T |
NB /T 33001-2018;NB/T 33008.1-2018;GB/T 18487.2-2017 |
Email: alisa@donduo.cn
Mob.: +86 153 7309 8804
WeChat: +86 153 7309 8804
Skype: +86 157 9298 1330
Whatsapp: +8615373098804
Add.: Liandong U Valley Shijiazhuang Science and Technology Innovation Port,No. 78, Tadong Street, Shijiazhuang Economic and Technological Development Zone, Gaocheng District, Shijiazhuang, Hebei Province