Home > Electrical Equipment & Supplies > Batteries > DD10030 30KW EV Charging Module

DD10030 30KW EV Charging Module

Short Description: 1. DC Max Input Current:0-60A 2. Input Frequency Range: 45Hz ~65Hz 3. DC Output Current:0~100A 4. DC Output Voltage: 200Vdc ~1000Vdc 5.DC Output Power: 30KW@ Voltage 6. Operating Temperature:-40℃~+75℃ 30KW @1000V Charger Power Module is specially designed for EV DC chargers. It has high efficiency, low fan noise, high power density and high reliability advantage.

Product Description

1.Characteristic curve

 

30KW EV Charging Module30KW EV Charging Module30KW EV Charging Module

2.Functional details

2 .1Short-circuit protection

After short circuit, the module will automatically shut down the protection (three short circuit lock mode: no output after protection, it can be restarted after 10 seconds. If it occurs again after three restart within 5 minutes, the module will lock and stop the output until the power is restored manually).

2.2 Output overvoltage protection

High voltage mode 1010V ± 10V; low voltage mode 510V ± 10V (four overvoltage lock mode: the module has no output after protection, the module can restart after 5 seconds, if the overvoltage occurs again after four restart within 5 minutes, the module will lock and stop the output until the power is restored manually).

2.3 Output undervoltage protection

High V mode 50V ± 5v; low V mode 25V ± 5V (no output after protection; command boot after recovery).

2.4 Input overvoltage protection

490 Vac ± 5V, 15V return difference (no output after protection; a command is required to boot after recovery).

2.5 Over-temperature protection function

The detection temperature reaches the preset value (no output after protection; command boot after recovery).

2.6 Input is missing phase protection

No output after protection; command to be started after recovery (no output after protection; command to be started after recovery).

2.7 Fan control

Control the fan speed according to ambient temperature and output current (automatic speed).

2.8 Remote communication

The protection signal of the module (AC, undervoltage, phase deficiency, output, undervoltage, overtemperature) and fault signal are transmitted to the background monitoring software in real time.

2.9 Remote monitoring

Feedback the real-time signal (voltage, current, power, temperature); the flow signal of each module to the background monitoring software.

2.10 Remote control

By the background monitoring software control module to turn on and off, both / floating charge conversion.

2.11 Remote adjustment

Adjust the current, pressure and power limit by the background monitoring software.

3.Technical Parameters

Product model

DD100030

Ambient condition

 

working temperature

-40℃ ~ + 70℃; -40℃ (± 4℃) module starter; 55 (± 2℃)℃

The above derated use;

Above 70℃ (± 4℃) for shutdown

storage temperature

- 40℃~85℃

relative humidity

95%, with no condensation

The atmospheric pressure is at an altitude of

79 kPa ~ 106 kPa; altitude <2000m; drop above 2000m

The amount of use

cooling-down method

Intelligent air cooling

Input Characteristics

input voltage

Three-phase line voltage 260 Vac ~ 485 Vac; undervoltage below 260 Vac, overvoltage above 485V, 260V ~320V drop, 320V ~485V full load output

incoming frequency

55 Hz±10Hz

Input power factor

≥0.98

Total harmonic distortion rate of the input current

5% (above half-load)

productiveness

95% (25 degree rated input / output full load efficiency)

Standby power consumption

10W

Input current overshoot

Peak input current Rated input current is 110%

number of phases

Three-phase + protected area

input currenton

0~60A

Output Characteristic

 

High pressure mode

Low pressure mode

Stable voltage output voltage regulation range

(200~1000)Vdc

(150~500)Vdc

Rated output voltage

1000V

500V

Rated output current

30A

60A

Adjustment range of current-limiting value

0.5A ≤I≤60A

0.5A ≤I≤100A

Output voltage ripple factor (25℃)

≤1(500Vdc~1000Vdc)

≤1(200Vdc~500Vdc)

Normal boot mode: startup time

3s≤t≤8s

3s≤t≤8s

Stable flow accuracy

≤±1%

≤±1%

Stable pressure accuracy

≤±0.5

≤±0.5

Me-flow imbalance

5% Rated output current (at 10%~100% load)

-universal relevance

5% Rated output current (at 10%~100% load)

-universal relevance

Newsletter Alarm

Communication interface

C AN

Maximum number of machines

60

Warning and status

Report the monitoring background via CAN bus or display in the panel LED

Physical Characteristics

Noise

<65dB (25℃, full load rated output)

Cooling-down method

Intelligent air cooling

Outline dimension

84mm * 300mm * 437.5mm (width * height * depth)

Quality

≤17kg

MTBF

400,000 hours (40℃)

Insulation resistance

 

 

The test voltage is 1000 Vdc, and the insulation resistance of the AC input to the case, the DC output and DC output to the case is> 100M Ω

Insulation strength

 

AC input to the case 3500 Vdc, DC output to the case and AC input output 4200 Vdc, 1 minute, no breakdown, no flying arc phenomenon, steady state leakage current less than 10 mA.

Safety &

EMC

Standard

GB/T

NB /T  33001-2018NB/T 33008.1-2018GB/T 18487.2-2017

 

Contact Us

Email: alisa@donduo.cn

Mob.: +86 153 7309 8804

WeChat: +86 153 7309 8804

Skype: +86 157 9298 1330

Whatsapp: +8615373098804

Add.: Liandong U Valley Shijiazhuang Science and Technology Innovation Port,No. 78, Tadong Street, Shijiazhuang Economic and Technological Development Zone, Gaocheng District, Shijiazhuang, Hebei Province

Home Contact us

Sign In

Username :

Password :