Home > Minerals & Metallurgy > Steel > 3 Ply 3mm Hts Wire

3 Ply 3mm Hts Wire

3 Ply 3mm HTS Wire is composited with 3 wires , each wire ‘s diameter is 3.00 mm. We produce this specification strictly as per Indian Standard IS 6006 . All specifications we can provide are 2-ply 2mm , 2-ply 3mm, 3-ply 3mm.

Product Description

3 Ply 3mm HTS Wire is composited with 3 wires , each wire ‘s diameter is 3.00 mm. We produce this specification strictly as per Indian Standard IS 6006 . All specifications we can provide are 2-ply 2mm , 2-ply 3mm, 3-ply 3mm.

The raw material is high carbon steel of such quality that when drawn to suitable round wire sizes and fabricated into proper strand sizes  properly stress relieved after stranding.

Raw material contains not more than 0.050 percent of sulphur and not more than 0.050 percent of phosphorus.

The length of lay for the two and three wire strands is uniform throughout and is  24 to 36 times the diameter of element wire. The wires in the strand are so formed that they donot unravel when the strand is cut and they do not fly out of position when the strand is cut without seizing.

There is no strand joints or strand splices in any length of the completed strand .

After stranding, all strands are subjected to a stress-relieving. Stress relieving is carried out as a continuous process on a length of strand.

The finished strand is uniform in diameter and is free from injurious flaws and imperfections.

The strand is not oiled or greased. 

 

ADVANTAGES

-Primary advantages

3 Ply 3mm HTS Wire is with very high tensile strength , low relaxation .

 

-Why should I buy this 3 Ply 3mm HTS Wire ?

We are the direct supplier of 3 Ply 3mm HTS Wire, the price is very competitive in the market.

 

-What makes this product different to other factory's 3 Ply 3mm HTS Wire?

.Three package dimension available .

 

USE

-Where can our3 Ply 3mm HTS Wire be used?

Pretensioned and posttensioned prestressed concrete construction.

Concrete products manufacture, such as concrete railway sleeper , precast beam , concrete pole/ concrete colum

 

SPECIFICATIONS

Designation Nominal Diameter of element wire Tolerance on diameter of element wire Nominal cross sectional area of strand Nominal mass of strand Breaking Load min 0.2 percent proof load
  mm mm mm2 kg/m N N
2-ply 2 mm 2.0 + -0.03 6.28 0.0493 12750 10840
2-ply 3 mm 3.0 + -0.03 14.14 0.111 25500 21670
3-ply 3 mm 3.0 + -0.03 21.21 0.166 38250 32460

 

PACKAGE

As per clients’ requirement

Home Contact us

Sign In

Username :

Password :